Fuelsave

Photovoltaics and diesel – the power of two.

The FuelSave is your one-stop solution for PV-Diesel hybrid power plants by two of the leading providers in their field of business: PRETTL group in diesel generator systems and KACO new energy in PV technology.

Benefits

  • Includes all necessary components – control unit, solar PV inverters, diesel generator, PV mounting system
  • On request, also comes with logistics, installation and commissioning services
  • Integrates PV systems of substantial size and power
  • Reduces fuel consumption and genset maintenance costs
  • Offers preconfigured packages ready for delivery
  • Can be adapted to individual needs
  • Allows for retrofitting of existing diesel generator systems
  • Extends operating time of gensets due to lower fuel consumption
  • Lowers emissions of CO2 and other air pollutants

Technical data - KACO FuelSave Controller

Electrical Data

AC power supply
Voltage
Frequency
Nominal input power

85 … 264 V*
47 … 63 Hz*
~ 30 W
Connections
AC mains input
Phase, neutral, PE


Recommend wiring rating


spring-type terminal (0.25 – 2.5 mm²
fine stranded wire; 0.25 – 4.0 mm²
solid wire) V
16 A
Digital inputs
Signal, ground


For recognition of diesel generator status (on/ off)
For recognition of diesel generator or utility grid mode

spring-type terminal (0.25 – 2.5 mm²
fine stranded wire; 0.25 – 4.0 mm²
solid wire)

6 digital inputs

1 digital Input



Digital outputs relay contacts
1 changeover contact


For load management


spring-type terminal (0.25 – 2.5 mm²
fine stranded wire; 0.25 – 4.0 mm²
solid wire)
I max.: 16 A; U max.: 250 V
Communication
Ethernet
USB
RS485


RS485 bus topology

RS485 cable length, cable type
RS485 baud rate


RJ45 socket
type A socket
spring-type terminal (0.25 – 2.5 mm²
fine stranded wire; 0.25 – 4.0 mm²
solid wire)
daisy chain, no star network layout
max. 1,200 m, min. 0.25 mm²,
two-core shielded cable
9600
Mechanical data
H x W x D
Weight
ambient temperature
Relative humidity
Protection rating
Max. altitude
615 x 400 x 236 mm
~12 kg
-0°C … +55 °C
15 % … 95 % non-condensing
IP66
2.000 m

Mechanical data
Requirements for installation at site
Mounting of controller
Special tools needed for installation

cool and shaded
Ethernet cable
Notebook / PC with Internet Explorer

Technical data - Measurement point

Electrical Data

AC power supply
Voltage


Nominal input power

230 / 240 V +/- 10 %, 50 / 60 Hz;
further voltages/frequencies on
request
< 3 VA


Measurement ranges
Voltage (direct connection)

Voltage (with external voltage transformer)


Current (with external current transformer)


Frequency

up to 300 V rms (phase-neutral) or
519 V rms (phase-phase)
primary: programmable (max. 400
kV); secondary: programmable
(max. 300 V)
primary: programmable (max.
10 kA); secondary: 1 or 5 A; 10 mA
… 20 kA
45 … 65 Hz
Connections

AC mains input
Phase, neutral, PE

screw connector (max. 2.5 mm²
fine stranded wire; max. 4.0 mm²
solid wire)


Measurement input
Voltages, currents

spring-type terminal (0.25 – 2.5
mm² fine stranded wire; 0.25 – 4.0
mm² solid wire)


Communication
RS485

screw connector (max. 2.5 mm²
fine stranded wire; max. 4.0
mm² solid wire))

Mechanical data
H x W x D
Operating temperature range
Relative humidity
Protection rating
323 x 250 x 163 mm
-10 ... +50 °C
< 95% non-condensing
IP66 (casing)

Installation
Installation close to genset(s), inverter(s), and loads to eliminate measurement errors caused by long wires
Current transformers (CTs) required, not included! (1 or 5 A)

Datasheet

Data Sheet Fuelsave

Format: PDF
Size: 232.36 KB